OBJECTIVE: To study the safety of percutaneous administration of Hongzhi gutong cataplasm. METHODS: Rabbits were taken for single dose in complete skin irritation test (n=4), single dose in damaged skin irritation test (n=4) and multiple doses in complete skin irritation test (n=4). The left and right sides of the skin respectively paste 3 cm×3 cm blank matrix and Hongzhi gutong cataplasm for 24 h (calculated by crude drug of 0.14 g). After removing tape 1, 24, 48, 72 h, the erythema and edema in hair removal site of rabbits in the former 2 tests were observed; after 24 h of administration, the rabbits in the last group were administrated again after exposing the administration area for 1 h, repeated 3 times, the erythema and edema in hair removal site after removing tape the first, second time and 1, 24, 48, 72 h in the third time were respectively observed. RESULTS: In the 3 experiments, the scores of erythema and edema of all rabbits were 0, and skin irritation was evaluated as no irritation. CONCLUSIONS: Hongzhi gutong cataplasm has no skin irritation in rabbits.