OBJECTIVE: To improve the method for the determination of 2 main components in Ticarcillin disodium and potassium clavulanate for injection. METHODS: HPLC was performed on the column of Waters XBridgeTM C18 with mobile phase of 0.01 mol/L ammonium dibasic phosphate solution (pH 7.0)-menthol (80 ∶ 20,V/V) at a flow rate of 1.0 mL/min, the detection wavelength was 220 nm, column temperature was 30 ℃, and injection volume was 20 μL. RESULTS: The linear range was 1.95-195.22 μg/mL for ticarcillin (r=0.999 9) and 0.12-12.18 μg/mL for clavulanate(r=0.999 9); RSDs of precision, stability (under 4 ℃) and reproducibility tests were lower than 1.0%;recoveries were 99.3%-100.5%(RSD=0.4%,n=9) and 99.2%- 101.0% (RSD=0.7%,n=9). CONCLUSIONS: The method is rapid, accurate and reliable, and can be used for the determination of 2 main components in Ticarcillin disodium and potassium clavulanate for injection.
关键词
高效液相色谱法替卡西林克拉维酸注射用替卡西林钠克拉维酸钾含量测定
Keywords
HPLCTicarcillinClavulanateTicarcillin disodium and potassium clavulanate for injectionContent determination