OBJECTIVE: To establish a method for the simultaneous determination of chlorogenic acid, hesperidin and baicalin in Shubiaoling granule. METHODS: HPLC was performed on the column of SAGA Tri-Sal C18 with mobile phase of acetonitrile - 0.5% phosphoric acid (gradient elution) at a flow rate of 1.0 ml/min, detection wavelength was 320 nm, column temperature was 30 ℃, injection volume was 10 μl. RESULTS: The linear range was 2.463-240.5 μg/ml for chlorogenic acid (r=0.999 9), 6.577-642.3 μg/ml for hesperidin (r=0.999 8) and 1.708-166.8 μg/ml for baicalin (r=0.999 8); RSDs of precision, stability and reproducibility tests were no more than 1.8%; recoveries were 97.02%-102.40% (RSD=1.9%,n=6),96.55%-100.20%(RSD=1.6%,n=6) and 97.51%-100.70% (RSD=1.2%,n=6), respectively. CONCLUSIONS: The method is simple, accurate with high sensitivity and good reprosucibility, and can be used for the simultaneous determination of chlorogenic acid, hesperidin and baicalin in Shubiaoling granule.