OBJECTIVE:To establish a method for simultaneous determination of rutin, quercetin and nuciferine in Heye granule. METHODS:HPLC was performed on the column of Hypersil ODS2 with mobile phase of acetonitrile-water(containing 0.3% phosphoric acid and 0.4% triethylamine)(gradient elution) at a flow rate of 1.0 ml/min, the detection wavelength was 256 nm, the column temperature was 25 ℃, and the injection volume was 10 μl. RESULTS: The linear range was 0.012-0.240 μg for rutin(r=0.999 9), 0.010 4-0.208 μg for quercetin (r=0.999 9) and 0.015-0.300 μg for nuciferine(r=0.999 9);RSDs of precision,stability and reproducibility tests were lower than 2.0%;recoveries were 98.5%-101.3%(RSD=1.1%,n=6),99.1%-101.6%(RSD=1.0%,n=6) and 98.9%-101.7%(RSD=1.2%,n=6). CONCLUSIONS:The method is simple, accurate and reliable, and can provide reference for quality control of Heye granule.